Status The status for an entry can be set to:
Permanent: This entry is currently in use and
will remain so after the next reset of
the switch.
DeleteOnReset: This entry is currently in use and
will remain so until the next reset.
Invalid: Removes the corresponding entry.
DeleteOnTimeOut:This entry is currently in use
and will remain so until it is aged
out. (Refer to Address Table Aging
Time on page 2-70.)
Other: This entry is currently in use but the
conditions under which it will
remain so differ from the preceding
values.
[Show] Displays the static address table sorted on VID as
the primary key and MAC address as secondary
key.
[More] Scrolls through entries in the static address table.
[Set] Adds the specified entry to the static address table,
such as shown in the following example:
VID : 1 MAC : 00-00-00-e8-34-22
Port : : 1
Status : Permanent
Parameter Description