SMC Networks SMC6724L3 Manual do Utilizador Página 299

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 618
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 298
L
INE
C
OMMANDS
4-13
Line Commands
You can access the onboard configuration program by attaching a VT100
compatible device to the server’s serial port. These commands are used to
set communication parameters for the serial port or Telnet (i.e., a virtual
terminal).
Command Function Mode Page
line Identifies a specific line for configuration and
starts the line configuration mode
GC 4-14
login Enables password checking at login LC 4-15
password Specifies a password on a line LC 4-16
exec-timeout Sets the interval that the command interpreter
waits until user input is detected
LC 4-17
password-thresh Sets the password intrusion threshold, which
limits the number of failed logon attempts
LC 4-18
silent-time* Sets the amount of time the management console
is inaccessible after the number of unsuccessful
logon attempts exceeds the threshold set by the
password-thresh command
LC 4-19
databits* Sets the number of data bits per character that
are interpreted and generated by hardware
LC 4-20
parity* Defines the generation of a parity bit LC 4-21
speed* Sets the terminal baud rate LC 4-22
stopbits* Sets the number of the stop bits transmitted per
byte
LC 4-23
show line Displays a terminal line's parameters NE,
PE
4-23
* These commands only apply to the serial port.
Vista de página 298
1 2 ... 294 295 296 297 298 299 300 301 302 303 304 ... 617 618

Comentários a estes Manuais

Sem comentários